100DM3 Classic Series

A rotating assembly of rollers compresses a flexible tube within a housing to create a vacuum to lift a chemical solution. The self-priming peristaltic pump is also referred to a hose, tube or dosing pump.

25 psi (1.7 bar) Double Head Adjustable Output Pump max 44 gpd (167 lpd)

How It Works

Stenner’s double head adjustable output metering pump is built with four detachable components: the motor, feed rate control, and two pump heads. Outputs are dependent upon three factors: the rpm of the motor gears, the percentage setting on the feed rate control, and the size of the peristaltic pump tube. All Stenner metering pumps have a 3-point roller design in the pump head, which acts as a check valve to prevent back flow, siphoning, overdosing and loss of prime.

The motor shaft rotates at a fixed rpm which drives the adjustable feed rate control to intermittently engage the roller assembly within the pump heads. The chemical solution in the pump tube is captured between the rollers as they rotate and compress the tube. As the rollers advance, the squeezed tube section regains its original form and generates a vacuum, creating the self- priming feature that delivers a constant flow unaffected by the outlet pressure.

STENNER PUMP COMPANY
Jacksonville, FL U.S.A    800.683.2378    904.641.1666    Copyright © 2007-2008 Stenner Pump Company. All Rights Reserved.