100DMP2 Specifications Summary

25 psi (1.72 bar) Double Head Fixed Output Pump max 20 gpd (76 lpd)

Outputs @ 60Hz
Gallons per day: 20.0
Gallons per hour: 0.83
Liters per day: 75.7
Liters per hour: 3.15
Ounces per minute: 1.78
Milliliter per minute: 52.57

Outputs @ 50Hz
Liters per day: 60.6
Liters per hour: 2.53
Milliliters per minute: 42.06

Discharge Pressure
0-25 psi (0-1.7 bar)

Voltage
120V 60Hz; 220V 60Hz
230V 50Hz; 250V 50Hz International

Motor
shaded pole; 44 rpm; 1/30 HP

Suction Lift
25' (7.6 m)

Maximum Operating Temperature
125° F (52° C)

Amp Draw
1.7 120V; 0.9 220V, 230V, 250V

Dimensions (l x w x h)
10.2 x 5.3 x 6.0 in
(25.9 x 5.3 x 6.0 cm)

Shipping Weight
9 lbs (4 kg)

Materials of Construction
All Housings: Lexan® polycarbonate plastic
Pump tube: Santoprene® FDA approved
Pump tube: Tygothane® FDA approved
Suction/discharge tubing & ferrules (1/4" & 6 mm): LDPE polyethylene,
NSF/FDA approved
Tube fittings, connecting nuts, check valve fitting,
weighted strainer: Type 1 Rigid PVC-NSF listed
All fasteners: Stainless Steel
  Lexan® is a registered trademark of General Electric.
  Santoprene® is a registered trademark of Advanced Elastomer system
  Tygothane® is a registered trademark of Saint-Gobain Performance Plastics
  Pellathane® is a registered trademark of The Dow Company
  Refer to the chemical resistance guide for pump tube material, PVC, LDPE compatibility

Agency listings
Santoprene®: UL, CSA , CE, NSF-61
Tygothane®: UL, CSA, CE

Accessories shipped with each pump
6 connecting nuts 1/4" or 3/8"
6 ferrules 1/4" & 6 mm OR 2 ferrules 3/8"
2 injection fittings
2 weighted strainer
2 20' roll of suction/discharge tubing 1/4" or 3/8" white or UV black
    OR 6 mm (Europe) white
2 spare pump tube
1 mounting bracket
1 installation manual

STENNER PUMP COMPANY
Jacksonville, FL U.S.A    800.683.2378    904.641.1666    Copyright © 2007-2008 Stenner Pump Company. All Rights Reserved.