100DMP4 Specifications Summary

25 psi (1.72 bar) Double Head Fixed Output Pump max 70 gpd (265 lpd)

Outputs @ 60Hz
Gallons per day: 70.0
Gallons per hour: 2.92
Liters per day: 265.0
Liters per hour: 11.04
Ounces per minute: 6.22
Milliliter per minute: 184.03

Outputs @ 50Hz
Liters per day: 212.0
Liters per hour: 8.83
Milliliters per minute: 147.22

Discharge Pressure
0-25 psi (0-1.7 bar)

Voltage
120V 60Hz; 220V 60Hz
230V 50Hz; 250V 50Hz International

Gear Motor
Shaded pole, class B, 1/30 HP;
approx. 44 rpm

Maximum Suction Lift
25' (7.6 m) vertical lift, based on water

Maximum Operating Temperature
125° F (52° C)

Amp Draw
1.7 120V; 0.9 220V, 230V, 250V

Dimensions (l x w x h)
10.2 x 5.3 x 6.0 in (25.9 x 5.3 x 6.0 cm)

Shipping Weight
9 lbs (4 kg)

Materials of Construction
All Housings: Polycarbonate
Pump Tube: Santoprene® FDA approved
Pump Head Latches: Polypropylene
Suction/Discharge Tubing, Ferrules 1/4" & 6 mm: Polyethylene, FDA approved
Tube Fittings: Gray fittings: Type 1 Rigid PVC, NSF listed, Black fittings PP, NSF listed
check Valve Fittings: Type 1 Rigid PVC, NSF listed
Connecting Nuts: PP or Type 1 Rigid PVC
Suction Strainer: PP or Type 1 Rigid PVC body with Type 1 Rigid PVC cap,
NSF listed; ceramic weight
All Fasteners: Stainless Steel
  
  Santoprene® is a registered trademark of Exxon Mobil Corporation
  Refer to the chemical resistance guide for compatibility

Agency listings (vary by models)
UL, CSA , CE, WQA to NSF 61

Accessories shipped with each pump
6 connecting nuts 1/4" or 3/8"
6 ferrules 1/4" & 6 mm OR 2 ferrules 3/8"
2 injection fittings
2 weighted strainers
2 20' rolls of suction/discharge tubing 1/4" or 3/8" white or UV black
    OR 6 mm (Europe) white
2 additional pump tubes
4 additional latches
1 mounting bracket
1 installation manual

STENNER PUMP COMPANY