25 psi (1.7 bar) Single Head Adjustable Output Pump max 60 gpd (227 lpd) uses #4 Pump Tube
The information within these charts is solely intended for use as a guide. The output data is an
approximation based on pumping water under a controlled testing environment. Many variables can affect
the output of the pump. Stenner Pump Company recommends that all metering pumps undergo field
calibration by means of analytical testing to confirm their outputs.

Outputs @ 60Hz
| FRC Setting | gpd | |
| L | 3.0 | |
| 1 | 6.0 | |
| 2 | 12.0 | |
| 3 | 18.0 | |
| 4 | 24.0 | |
| 5 | 30.0 | |
| 6 | 36.0 | |
| 7 | 42.0 | |
| 8 | 48.0 | |
| 9 | 54.0 | |
| 10 | 60.0 |
Additional Output Ranges
Gallons per hour: 0.13 to 2.5
Liters per day: 11.4 to 227.1
Liters per hour: 0.48 to 9.46
Ounces per minute: 0.27 to 5.33
Milliliters per minute: 7.92 to 157.71
Outputs @ 50Hz
| FRC Setting | lpd | |
| L | 9.1 | |
| 1 | 18.2 | |
| 2 | 36.3 | |
| 3 | 54.5 | |
| 4 | 76.7 | |
| 5 | 90.8 | |
| 6 | 109.0 | |
| 7 | 127.2 | |
| 8 | 145.3 | |
| 9 | 163.5 | |
| 10 | 181.7 |
Additional Output Ranges
Liters per hour: 0.38 to 7.57
Milliliters per minute: 6.32 to 126.18
More Information
Dimensions
Specifications Summary
Motor Exploded View
Motor Subassemblies and Service Kits
Feed Rate Control Exploded View
Feed Rate Control Subassemblies and Service Kits
Pump Head Exploded View
Pump Head Subassemblies and Service Kits
Pump Tubes
Injection Fitting
Suction/Discharge Tubing
Accessory Kits
Miscellaneous Parts
Tank Systems
How to Create an Item Number